Grid in Chile: 12 / 23 kV HV, 380 V LV, 50 Hz.

  • HV12 / 23 kV
  • LV380 V
  • Frequency50 Hz
  • Conformity scheme— (confirmed per order)
  • RegionLatin America

Matching product lines

Other HV ratings on request

LV to the destination grid on request

Specifying a distribution transformer for Chile

Chilean distribution networks run at 50 Hz, with medium voltage up to 23 kV. The medium-voltage level, the transformer type and the approved list differ by network operator, so check the operator’s own specification before asking for a quotation.

Medium voltage, low voltage and frequency

ItemValue and source
Frequency50 Hz nominal in distribution systems (CNE technical standard for distribution service quality, art. 1-5)
Medium voltage (MT)Above 1 kV and up to 23 kV (same standard)
Low voltage (BT)1 kV or below; nominal 220 V phase-to-neutral in three- and four-wire three-phase systems (same standard), i.e. 380/220 V
Enel Distribución Chile12 kV and 23 kV primary, 0.4 kV secondary (0.4–0.231 kV on some compact units), in its list of approved transformers

Enel’s approved-equipment list (February 2026) is the most concrete public picture of what a large Chilean operator buys. Check your own project’s operator: a different operator can use different voltages.

What Enel Distribución Chile lists as approved

Type in Enel’s listRating range in the listPrimary voltageEnel specification
Overhead three-phase (aéreo)45–500 kVA12 kV and 23 kVGST001
Compact substation transformer (centro compacto)400–1000 kVA12 kV and 23 kVGST001
Pad-mounted (superficie)300–1000 kVA12 kV and 23 kVE-MT-020
Underground, oil-immersed (subterráneo, radial sumergible)500–1000 kVA12 kV and 23 kVE-MT-021

Single-phase overhead units of 15 kVA (12 kV and 23 kV) are also listed. The list names each approved manufacturer and model: a transformer that is not on the operator’s list cannot be assumed to be accepted for its network.

SEC certification

Electrical products that Chile places under mandatory certification must carry a certificate from a certification body authorised by the SEC (Superintendencia de Electricidad y Combustibles). The products covered are set by the Ministry of Energy by resolution, and SEC publishes them in its product search system. Foreign certificates can be recognised through the procedure in SEC Resolución Exenta N° 21271.

Before ordering, check in SEC’s product search whether the transformer type you need is on the mandatory list and which protocol applies, and tell us what you find in your enquiry.

What our published ratings cover

  • Oil-immersed S11 / S13: the published values are 50 Hz guarantees, which matches the Chilean network frequency. S11 (10/11 kV class): LV options 380, 400, 415 and 433 V; vector groups Dyn11, Yyn0 and Yzn11; tapping ±2 × 2.5 %; IEC 60076. S13: 0.4 kV LV; vector groups Dyn11 and Yyn0.
  • S11 is published for 6 / 6.3 / 10 / 10.5 / 11 kV (30–4500 kVA) and for 20 kV (30–1600 kVA). 12 kV and 23 kV primaries, and any operator-specific design or approved-list requirement: on request.
  • Dry-type SC(B)11 / SC(B)13: published 6–15 kV, 30–2500 kVA, so 12 kV falls inside the published range.
  • Pad-mounted units on this site are IEEE/ANSI C57.12 at 60 Hz; for a 50 Hz Chilean network they are quoted on request.

Send with your enquiry

  • Network operator and site (city, altitude)
  • Rated power (kVA), HV (12 or 23 kV) and LV (380 or 400 V), vector group, tapping range
  • Type: overhead, compact substation, pad-mounted, underground or dry-type; indoor or outdoor
  • The operator’s specification number or approved-manufacturer requirement, if any, and whether an SEC certificate is required
  • Quantity and required delivery date